SIKV are produced in two modifications:
Upon request, SIKV is completed with a specialized device for data processing of primary transducers of flow rate, temperature and pressure installed in SIKV.
Personnel fire alarm control system is developed and manufactured according to TU 28.99.39-020-20676863-2018
Example of notation when ordering products:
SIKV-4,0-1 (2)-U1(ХЛ1), where:
4,0 - nominal pressure, MPa;
1(2) - version (1-open placement on the frame-base, 2- in block-boxes);
У1 (ХЛ1) - climatic version in accordance with GOST 15150.
|
Name |
Designation |
|
Nominal pressure, MPa |
1,6, 2,5, 4,0, 6,3 |
|
Medium temperature, оC |
+5-+50 |
|
Operating medium |
formation water |
|
Water content, mg/l: mechanical impurities oil products |
not more than 50 not more than 50 |
|
Water loss, MPa |
not more than 0,10 |
|
Operation mode |
continuous |
|
Relative error, %: - Flow measurement (sensor) - Flow measurement (transmitter) - Pressure measurement (sensor) |
± 0,5 ± 0,05 ± 0,5 |
|
Absolute temperature error (sensor), °C |
± 0,2 |
|
Accuracy class: Pressure gauge thermometer |
0,6 1,0 |
|
Service life, years |
15 |